For example: Agilent E4440A or Anritsu 68369
Current Probe Assembly

Model:80I-600A

Manufactured by: Fluke

Category:Probes

Fluke 80I-600A - Probes

Fluke 80I-600A Overview

  • Input Current Range: 1A to 600A
  • Output: 1 milliamp per ampere of input current (1mA/A)
  • Accuracy: ±2% of reading, 50 Hz to 1 kHz ±3% of reading (typical), 30 Hz to 50 Hz or 1 kHz to 10 kHz.
  • Working Voltage: 750V ac rms maximum
  • Maximum Conductor Size: 50.8 mm (2 inch.)
  • Shunt (load) Resistance: less than 12 at multimeter input to maintain specified accuracy
  • Typical Bandwidth: -10% at 10 Hz and 50 kHz (1A, 400 Hz reference, excludes multimeter response)
  • Usable Current Range: 0.1A to 2000A, 5 seconds maximum above 600A
  • Safety: Protection Class Class II as defined in IEC 348 and ANSI C39.5


The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes.

A clamp-on, 1000-turn coil designed into the probe allows measurements to be made without breaking the circuit under test. The coil serves as the secondary of a current transforme

How can we help you with today?