For example: Agilent E4440A or Anritsu 68369
80T-IR Non-Contact Infrared Temperature Probe
-
Do you have a 80T-IR you want to sell?
We buy used equipment!
Learn about selling - Only need this item for a short time? Learn about renting
Fluke 80T-IR Overview
- Temperature Range:
- -18 to 260 C (0 to 500 F)
- Accuracy:
- ‚± 3% of reading or ‚± 3‚ºC (‚±5‚ºF), whichever is greater
- 18‚ºC to 28‚ºC (64‚ºF to 82‚ºF) ambient operating temperature
- Spot Size Ratio:
- 4:1
- Minimum Spot Size:
- 0.1 inch diameter
- Output Signal:
- 1mV per deg C or F (switchable)
- Safety Rating:
- Complies with IEC Publication 1010-1-1990 including Ammendment 1
- CSA C22.2 No. 231
- ANSI/ISA-S82.01 and .03 Safety Standards
The Fluke 80T-IR, Non-Contact Infrared Temperature Probe, that is compatible with any DMM with 10 MOhms input impedance, standard diameter banana jacks, and mV dc capability. Ideal for maintenance applications where object to be measured is hazardous to touch, is moving, easily contaminated, or difficult to reach.