For example: Agilent E4440A or Anritsu 68369
DMM Handheld 3.75 Digital/Analog

Model:85-3

Manufactured by: Fluke

Category:Multimeters

Fluke 85-3 - Multimeters

Fluke 85-3 Overview

Fluke 85 Series III Digital Multimeter Specifications General Specifications DCV Maximum Voltage: 1000V Accuracy:

  • Fluke 83 III: ±(0.1%+1)
  • Fluke 85 III: ±(0.08%+1)
  • Fluke 87 III: ±(0.05%+1)
  • Fluke 87/E: ±(0.05%+1) Maximum Resolution: 0.1 mV ACV Maximum Voltage: 1000V Accuracy:
  • Fluke 83 III: ±(0.5%+2)
  • Fluke 85 III: ±(0.7%+2)
  • Fluke 87 III: ±(0.7%+2)
  • Fluke 87/E: ±(0.7%+2) Maximum Resolution: 0.1 mV DC Current Maximum Amps: 10A Amps Accuracy:
  • Fluke 83 III: ±(0.4%+2)
  • Fluke 85 III: ±(0.2%+2)
  • Fluke 87 III: ±(0.2%+2)
  • Fluke 87/E: ±(0.2%+2) Maximum Resolution:
  • Fluke 83 III: 0.01 mA
  • Fluke 85 III: 0.1 µA
  • Fluke 87 III: 0.1 µA
  • Fluke 87/E: 0.1 µA AC Current Maximum Amps: 10A Amps Accuracy:
  • Fluke 83 III: ±(1.2%+2)
  • Fluke 85 III: ±(1.0%+2)
  • Fluke 87 III: ±(1.0%+2)
  • Fluke 87/E: ±(1.0%+2) Maximum Resolution: 0.1 µA Resistance Max Resistance: 40 MW Accuracy:
  • Fluke 83 III: ±(0.4%+1)
  • Fluke 85 III: ±(0.2%+1)
  • Fluke 87 III: ±(0.2%+1)
  • Fluke 87/E: ±(0.2%+1) Maximum Resolution: 0.1W Capacitance 1 nF-5µF Frequency 0.5 Hz to 200 kHz
  • How can we help you with today?