Do you have a PM2811 you want to sell?
We buy used equipment!
Learn about selling - Only need this item for a short time? Learn about renting
Fluke PM2811 Overview
RangeOutput Voltage: 0 to 30V
Output Current: 0 to 10A
Output Power: 60W
Overvoltage protection: 2 to 32VAccuracy(at calibration temperature)
Output Voltage: ± (0.04% of setting + 10 mV)
Output Current: ± (0.1% of setting + 50 mA)
Over Voltage Protection: ± (0.5 % of setting + 150 mV)Temperature coefficientOutput Voltage: (0.016% of setting + 2 mV) /K
Output Current: (0.05% of setting + 2 mA) /KLong term drift(in an 8 hour period)
Output Voltage: 0.04% of setting + 5 mV
Output Current: 0.05% of setting + 10 mAProgramming Resolution(12 bit)
Output Voltage: 7.5 mV/LSB)
Output Current: 2.5 mA/LSB)
Over Voltage Protection: 7.5 mV/LSB)Source Effect(for any line voltage change within rating)
Voltage: ± (0.01% of setting + 2 mV)
Current: ± (0.02% of setting + 2 mA)Load Effect(load change 10% to 90% or 90% to 10% full load)
Constant Voltage: ± (0.01% of setting + 5 mV)
Constant Current: ± (0.02% of setting + 5 mA)Load cross regulationNegligible for both voltage and currentOutput Noise (PARD)Constant Voltage pp/rms (40 Hz to 30 MHz): 15 mV/3 mV
Constant Current rms: 10 mA
Switching Frequency: approx. 20 kHz