For example: Agilent E4440A or Anritsu 68369
60MHz 2CH 100MSa/s Oscilloscope Monochrome

Model:GDS-806S

Manufactured by: Instek

Category:Oscilloscopes

Instek GDS-806S - Oscilloscopes

Instek GDS-806S Overview

  • 60MHz Bandwidth With MONO Display
  • 125k Memory and 12 Division Horizontal Display
  • 25GS/s Sampling Rate for Repetitive Waveforms
  • Advanced Trigger : Pulse Width , TV Line, Event Delay and Time Delay
  • Go/NoGo , Auto Setup Sequence and TTF Function
  • Built-In Help Menu, Multi-Language and FREE PC Software
  • Standard Interface: RS-232C
  • Optional Interface: GPIB, Printer Port and USB 2.0

Display System
Display Device
Display Contrast
Waveform Display Graticule
Mono (320 x 240)
Adjustable
8 x 10 divisions (8 x 12 when menu off)
Vertical System
Bandwidth
Channels
Vertical Resolution
Vertical Sensitivity
Vertical Accuracy
Rise Time
Input Coupling
Input Impedance
Polarity
Max. Voltage Between Signal &
common at Input BNC
Waveform Signal Process
Offset Range
BW Limit
60MHz
2
8-bit
2mV/div ~ 5V/div
±3%
<5.8ns
AC , DC , Ground
1M? ± 2% , ~18pF
Normal and Invert
300V ( DC+AC peak ) , CATII

CH1 + CH2 , CH1 - CH2 , FFT
2mV/div~50mV/div : ± 0.5V; 100mV/div~500mV/div : 1V/div~5V/div : ±50V
20MHz ( -3dB )
Horizontal System
Time Base Range
Time Base Mode
Time Base Accuracy
Delay Range
1ns/div ~ 10s/div ( 1-2-5 increments ), Roll : 250ms/div ~ 10s/div
Main , Window , Window Zoom , Roll , X-Y
± 0.01%
Pre-trigger : 20 div
Signal Acquisition
Real-Time Sample Rate
100MS/s maximum on each channel
System
Equivalent Sample Rate
Record Length
Peak Detection
Acquisition Mode
Average
25GS/s E.T. maximum on each channel
125h/CH
10ns (500ns/div ~ 10s/div)
Sample , Peak Detect , Average
2 , 4 , 8 , 16 , 32 , 64 , 128 , 256
Trigger
Trigger Source
Mode

Coupling
Sensitivity

CH1 , CH2 , Line , Ext
Auto Level , Auto , Normal , Single , TV , Time Delay , Event Delay , Edge,
Pulse Width , AC , DC , HF , LF , Noise Reject
AC , DC , HF , LF , Noise Reject
DC ~ 25MHz : Approximate 0.5div or 5mV
25MHz ~ 60MHz : Approximate 1.5div or 15mV
X - Y Mode
X-Axis Input / Y-Axis Input
Phase Shift
Channel 1 / Channel 2
± 3° at 100 kHz
Cursor and Measurement
Auto Voltage Measurement
Auto Time Measurement

Cursor Measurement

Vpp , Vamp , Vavg , Vrms , Vhi , Vlo , Vmax , Vmin
Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width,
Duty Cycle
Voltage difference between cursors (?V), Time difference between
cursors (?T), Frequency difference between cursors (1/?T)
Frequency Counter
Readout Resolution
Frequency Range
Signal Source
6 digits
AC Coupled, 20Hz~rated bandwidth ; resolution: 10Hz
All available trigger source except the Pulse Width & Video Trigger mode
Adjustable Probe
Frequency Range
1 kHz ~ 100 kHz 1KHz / STEP
Calibration Signal
Duty Cycle
5% ~ 95% 5% / STEP
External Trigger
Range
Sensitivity
Input Impedance
Maximum Input
± 15V
DC ~ 25MHz : ~ 50mV ; 25 ~ 60MHz : ~ 100mV
1M? ± 2%, ~ 18pF
300V ( DC + AC peak ) , CATII
Control Panel Function
AutoSet

Save/Recall
Waveform Trace Save/Recall
"Autoset" can adjust vertical ( Volt/div ), Horizontal ( Sec/div)
and Trigger level automatically
Up to 15 sets of measurement conditions can be saved and recalled
2 sets of waveform can be saved and recalled
Interface
Standard
Optional Opt. 01
Optional Opt. 11
RS-232C
GPIB Interface
USB, Printer Port, Go/NoGo Output
Power Source
100V ~ 240V AC 47Hz ~ 63Hz , Auto selection
Accessories
Instruction Manual x 1 , Power Cord x 1 , Probe x 2
Dimensions and Weights
310W x 142H x 254D (mm) , Approximate 4.1 kg

How can we help you with today?