For example: Agilent E4440A or Anritsu 68369
.01 MHz - 220 MHz, 500W & 200 MHz - 1 GHz, 100W
-
Do you have a CMX 5001 you want to sell?
We buy used equipment!
Learn about selling - Only need this item for a short time? Learn about renting
Instruments for Industry CMX 5001 Overview
Features:
- Digital Display Monitors: Power Supply Currents, Voltage, Forward RF Power, Reflected RF Power, (Optional on CMX Models) Total Hours, Operate Hours
- Status Indicators: Power On, Standby, Operate
- Faults: Overcurrent, VSWR Overload, Thermal Overloads, Air Flow Power Supply
- Controls: AC Breaker On/Off, Standby, Operate, Fault Reset, Local/Remote
- GPIB IEEE 488 Remote Control
- Internal Pre-amplification to obtain rated output power with an input level of 0 dBm or less
- RF Input/Output Connectors on the Front Panel
- Internal Systems Diagnostics
- ALC, Automatic Leveling Control
- Total/Operate Elapsed Time Metering in Hours
- RF Safety Door interlock, BNC Connector
- Ease of Maintenance
- Designed to meet the safety requirements of the IEC-348 and Underwriters Labratory of American Standards
- Broadband Coverage
- Applications Include: MIL-STD-461/462, RTCA/D0-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, Broadband Communications.
- Frequency Range .01-1000 MHz
- Rated Output Power (min. Saturated) 500/100 Watts
- 500W @ 10 kHz - 250MHz
- 100W @ 200MHz - 1 GHz
- Small Signal Gain 57/50 dB
- Linear Power (nominal) 55 Watts
- Prime Power 115 VAC + -10%, 50/60 Hz, Single Phase
- Input / Output Impedance 50 ohms CSWR 2.0:1 (max 2.5:1)
- RF Input / Output Connectors Type N Female on Front Panel
- RF Sample Port Type N Female on Front Panel
- Modulation AM/FM/Pulse
- Spurious -50 dBc
- Harmonics -20 dBc