For example: Agilent E4440A or Anritsu 68369
Transient Limiter w/Hi Pass Filter
-
Do you have a 11947A you want to sell?
We buy used equipment!
Learn about selling - Only need this item for a short time? Learn about renting
Keysight / Agilent 11947A Overview
In precompliance applications where a spectrum analyzer is used for measurements instead of an EMI receiver, it is always a good idea to use a transient limiter. The Agilent 11947A Transient limiter protects the spectrum analyzer input from damage caused by high-level transients from line impedance stabilization networks (LISNs) during EMI testing for conducted emissions.
Features:
- Protects the spectrum analyzer input from damage caused by high-level transients
- Frequency Range: 9 kHz to 200 MHz
- Insertion Loss: 10 dB
- Maximum Input Level: Continuous: 2.5 W (+34 dBm), Pulse: 10 kW for 10 µS, DC:±12 V
Keysight / Agilent 11947A All Available Options