For example: Agilent E4440A or Anritsu 68369
Mobile Com PS 15V/3A Batt Emul Dual

Model:66319B

Manufactured by: Keysight / Agilent

Category:Power Supplies

Keysight / Agilent 66319B - Power Supplies

Keysight / Agilent 66319B Overview

The Agilent Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and an Agilent-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

The Agilent 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a ½ rack box) and eliminates the need for two separate power supplies.

Output Ratings

  • Voltage: 0 to 15 V
  • Current: 0 to 3 A
  • Peak Current for up to 7 ms: 5 A

Programming accuracy at 25°C ±5°C

  • Voltage: 10 mV
  • + Current: 1.33 mA

DC Readback Accuracy

  • Voltage: 0.03% + 5 mV
  • Current (-3 A to + 5 A): 0.2% + 0.5 mA
  • Current (-1 A to + 1 A): 0.1% + 0.2mA
  • Current (-20 mA to + 20 mA): 0.1% + 2.5 µA

Transient Response

  • 40 mV drop, <20 µs transient response time

Keysight / Agilent 66319B All Available Options Expand

How can we help you with today?