Agilent E4440A PSA Spectrum Analyzer, 3 Hz to 26.5 GHz
Keysight / Agilent E4440A-115-1DS-219-226-512-AYZ-B7J Overview
Key Features &
Specifications
Performance
- +/-0.19 dB absolute amplitude accuracy
- -155 dBm (-169 dBm w/preamp) displayed average noise level (DANL)
- -118 dBc/Hz phase noise at 10 kHz offset
- 81 dB W-CDMA ACLR dynamic range
Analysis bandwidth
- 10 MHz analysis bandwidth (Option B7J for the Basic mode)
- Optional 40 or 80 MHz analysis bandwidth to capture and measure complex
signals.
- -78 dB (nominal) third order intermodulation for 40 or 80 MHz analysis
bandwidth
- Up to 300 MHz analysis bandwidth for calibrated VSA measurements
Keysight / Agilent E4440A-115-1DS-219-226-512-AYZ-B7J Options
115 512 MB user memory
1DS RF internal preamplifier
219 Noise figure measurement personality
226 Phase noise measurement personality
512 STND (TYPE N CONNECTOR)
AYZ External Mixing
B7J Digital demodulation hardware
Keysight / Agilent E4440A-115-1DS-219-226-512-AYZ-B7J All Available Options
Other Options:
015 6 GHz return-loss Measurement Accessory Kit
033 Measuring receiver connector accessory kit
071 Digital Demodulation H/W for S/N USUS4142/MY4140 Changed ot B7J on newer models
0B0 Do not include manuals
0B1 Add Manual Set
0BV Service Documentation, Component Level
0BW Service Documentation, Assembly Level
107 Audio input 100 kOhm
110 RF/uW internal preamplifier
111 USB device side I/O interface ( Shipped Standard on S/N >MY4614)
115 512 MB user memory ( Shipped Standard on S/N >MY4614)
117 Secure memory erase
119 Noise Figure Hardware Kit . Standard on all models S/N > US4222/MY4100.
122 80 MHz bandwidth digitizer
123 Switchable MW preselector bypass
124 Y-axis video output
140 40 MHZ Bandwidth Digitizer
1A7 PSA Series ISO 17025 compliant calibration with test data
1CM Rackmount Kit
1CN Handle kit
1CP Rack mount kit with handles
1CR Rack slide kit
1DS RF internal preamplifier
202 GSM w/EDGE Measurement Personality
204 1xEV-DO Measurement Personality
210 HSDPA/HSUPA measurement personality
211 TD-SCDMA measurement personality
212 TD-SCDMA Modulation Analysis Measurement Personality
213 HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality
214 1XEV-DV measurement personality
215 External Source Control Measurement Personality
217 WLAN Measurement Personality
219 Noise figure measurement personality
226 Phase noise measurement personality
230 Benchlink web remote control software
233 Built-in measuring receiver personality
235 Wide BW digitizer external cal wizard
239 EMC measurement personality
23A AM/FM/PM triggering for measuring receiver
23B CCITT filter for audio measurements
241 Flexible digital modulation analysis
266 Programming code compatibility suite measurement personality (8566/8568/8590 series/8560 series)
423 Switchable MicrowOptionave Preselector Bypass. Available for all models with S/N
426 Gated Sweep Hardware. Standard on all models >S/N US/MY4336.
511 Without digital demodulation hardware
512 STND (TYPE N CONNECTOR)
516 40 MHz BW IF output - low band
517 Boris DIF --with opt 122 or 124
518 Natasha DIF -- no opt 122 or 124
520 Preselector bias cable - no opt HNQ
521 STD WB Analog IF board
524 SCSI interface card and dress panel
627 Required for all options except HT1
628 Required for all options except 111
630 Required for option 110 without 123
631 Required for 123 without 110
632 Required for option 110 with 123
633 Required for all options except HS1, HS7 and HT1
701
A6J PSA Series ANSI Z540 compliant calibration with test data
AB1 Korea Quick Users Guide (Korean localization)
AB2 China Quick Users Guide (Chinese localization)
ABA U.S. Quick Users Guide (English localization)
ABD Germany Quick Users Guide (German localization)
ABE Spain Quick Users Guide (Spanish localization)
ABF France Quick Users Guide (French localization)
ABJ Japan Quick Users Guide (Japanese localization)
ABZ Italy Quick Users Guide (Italian localization)
ANE 64 MB Flash Ram Memory. Shipped Standard on all 46A/47A/48A Models. Shipped Standard on all models >US/MY4222
ATP01 ATP Lead-time Item for E4440A-AYZ, 210,211,214 NPI Introduction
ATP02 ATP LEADTIME ITEM FOR E4440A-H20
ATP03 ATP LEADTIME ITEM FOR E4440A-H25
ATP04 ATP LEADTIME ITEM FOR E4440A-H7L
ATP05 ATP LEADTIME ITEM FOR E4440A-HB2
ATP06 ATP LEADTIME ITEM FOR E4440A-HGT
ATP07 ATP LEADTIME ITEM FOR E4440A-HN9
ATP08 ATP LEADTIME ITEM FOR E4440A-JMP
AYZ External Mixing
B78 CDMA2000 Measurement Personality
B7J Digital demodulation hardware
BAB APC 3.5 Connector
BAC CDMAOne Measurement Personality
BAE NADC,PDC Measurement Personality
BAF W-CDMA Measurement Personality
C01 RF connector color code
C5X 5x Z540 Compliant Calibration Service Agreement
D7J
E9285B-H01 DVB Specific software suite
H10 RTCASS program option
H20 20 MHz IF Output on rear panel.
H25 25 MHz IF output on rear panel
H26 High Band Preamplifier (Discontiued) Replaced by option 110.
H70 70 MHz IF Output
H7L Auxiliary Wideband Log Video Output
HB2 21.4 MHz IF Output
HB6 Prevention of unauthorized firmware upgrade
HBA Rear Panel RF Input
HGT Allows Gate width of less than 10 uSec.
HN8 Wideband Preselector Bypass (No Preselector)
HN9 80 MHz wide baseband IF output at 321.4 MHz for frequencies less than 3.05 GHz
HNQ I/Q Front Panel Output connectors with hardware for use with 89600A.
HS1 Increase level of security write protects to user files
HS7 Security erase software
HT1 GPS Interface Card for Trimble GPS
HWB Analog IF output from option 122
HY7 Improved Gain 70 MHz IF Output
JMP Rear panel jumper cable
N6171A MATLAB Software
N6171A-M01 MATLAB - Basic Package
N6171A-M02 MATLAB - Standard Package
N6171A-M03 MATLAB - Advanced Package
N9051A Pulse measurement software
N9051A-2FP Pulse measurement software, fixed, perpetual, license
N9051A-3FP Phase & Frequency Measurements
N9051A-4FP Extended Analysis & Statistics
OBO Delete Manual
PS-S20-01 Recommended Startup assistance
R-50C-001 Standard Calibration w/data. Replaced UK6
R-50C-002 Traceable Calibration standards compliant initial receipt. (ANSI-Z540/17025)
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
R-52A-001-3 3 Year Calibration License (Commercial)
R-52A-001-L Lifetime Calibration License (Commercial)
R-52A-002-3 3 Year Calibration License (Z540/17025)
R-52A-002-L Lifetime Calibration License (Z540/17025)
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UE2 Firmware Kit. CD-ROM.
UK6 Commercial Cal Certificate with Datarel="">
How can we help you with today?