015 |
6 GHz return-loss Measurement Accessory Kit |
033 |
Measuring receiver connector accessory kit |
071 |
Digital Demodulation H/W for S/N USUS4142/MY4140 Changed ot B7J on newer models |
0B0 |
Do not include manuals |
0B1 |
Add Manual Set |
0BV |
Service Documentation, Component Level |
0BW |
Service Documentation, Assembly Level |
107 |
Audio input 100 kOhm |
110 |
RF/uW internal preamplifier |
111 |
USB device side I/O interface ( Shipped Standard on S/N >MY4614) |
115 |
512 MB user memory ( Shipped Standard on S/N >MY4614) |
117 |
Secure memory erase |
119 |
Noise Figure Hardware Kit . Standard on all models S/N > US4222/MY4100. |
122 |
80 MHz bandwidth digitizer |
123 |
Switchable MW preselector bypass |
124 |
Y-axis video output |
140 |
40 MHZ Bandwidth Digitizer |
1A7 |
PSA Series ISO 17025 compliant calibration with test data |
1CM |
Rackmount Kit |
1CN |
Handle kit |
1CP |
Rack mount kit with handles |
1CR |
Rack slide kit |
1DS |
RF internal preamplifier |
202 |
GSM w/EDGE Measurement Personality |
204 |
1xEV-DO Measurement Personality |
210 |
HSDPA/HSUPA measurement personality |
211 |
TD-SCDMA measurement personality |
212 |
TD-SCDMA Modulation Analysis Measurement Personality |
213 |
HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality |
214 |
1XEV-DV measurement personality |
215 |
External Source Control Measurement Personality |
217 |
WLAN Measurement Personality |
219 |
Noise figure measurement personality |
226 |
Phase noise measurement personality |
230 |
Benchlink web remote control software |
233 |
Built-in measuring receiver personality |
235 |
Wide BW digitizer external cal wizard |
239 |
EMC measurement personality |
23A |
AM/FM/PM triggering for measuring receiver |
23B |
CCITT filter for audio measurements |
241 |
Flexible digital modulation analysis |
266 |
Programming code compatibility suite measurement personality (8566/8568/8590 series/8560 series) |
423 |
Switchable MicrowOptionave Preselector Bypass. Available for all models with S/N
|
426 |
Gated Sweep Hardware. Standard on all models >S/N US/MY4336. |
511 |
Without digital demodulation hardware |
512 |
STND (TYPE N CONNECTOR) |
516 |
40 MHz BW IF output - low band |
517 |
Boris DIF --with opt 122 or 124 |
518 |
Natasha DIF -- no opt 122 or 124 |
520 |
Preselector bias cable - no opt HNQ |
521 |
STD WB Analog IF board |
524 |
SCSI interface card and dress panel |
627 |
Required for all options except HT1 |
628 |
Required for all options except 111 |
630 |
Required for option 110 without 123 |
631 |
Required for 123 without 110 |
632 |
Required for option 110 with 123 |
633 |
Required for all options except HS1, HS7 and HT1 |
701 |
|
A6J |
PSA Series ANSI Z540 compliant calibration with test data |
AB1 |
Korea Quick Users Guide (Korean localization) |
AB2 |
China Quick Users Guide (Chinese localization) |
ABA |
U.S. Quick Users Guide (English localization) |
ABD |
Germany Quick Users Guide (German localization) |
ABE |
Spain Quick Users Guide (Spanish localization) |
ABF |
France Quick Users Guide (French localization) |
ABJ |
Japan Quick Users Guide (Japanese localization) |
ABZ |
Italy Quick Users Guide (Italian localization) |
ANE |
64 MB Flash Ram Memory. Shipped Standard on all 46A/47A/48A Models. Shipped Standard on all models >US/MY4222 |
ATP01 |
ATP Lead-time Item for E4440A-AYZ, 210,211,214 NPI Introduction |
ATP02 |
ATP LEADTIME ITEM FOR E4440A-H20 |
ATP03 |
ATP LEADTIME ITEM FOR E4440A-H25 |
ATP04 |
ATP LEADTIME ITEM FOR E4440A-H7L |
ATP05 |
ATP LEADTIME ITEM FOR E4440A-HB2 |
ATP06 |
ATP LEADTIME ITEM FOR E4440A-HGT |
ATP07 |
ATP LEADTIME ITEM FOR E4440A-HN9 |
ATP08 |
ATP LEADTIME ITEM FOR E4440A-JMP |
AYZ |
External Mixing |
B78 |
CDMA2000 Measurement Personality |
B7J |
Digital demodulation hardware |
BAB |
APC 3.5 Connector |
BAC |
CDMAOne Measurement Personality |
BAE |
NADC,PDC Measurement Personality |
BAF |
W-CDMA Measurement Personality |
C01 |
RF connector color code |
C5X |
5x Z540 Compliant Calibration Service Agreement |
D7J |
|
E9285B-H01 |
DVB Specific software suite |
H10 |
RTCASS program option |
H20 |
20 MHz IF Output on rear panel. |
H25 |
25 MHz IF output on rear panel |
H26 |
High Band Preamplifier (Discontiued) Replaced by option 110. |
H70 |
70 MHz IF Output |
H7L |
Auxiliary Wideband Log Video Output |
HB2 |
21.4 MHz IF Output |
HB6 |
Prevention of unauthorized firmware upgrade |
HBA |
Rear Panel RF Input |
HGT |
Allows Gate width of less than 10 uSec. |
HN8 |
Wideband Preselector Bypass (No Preselector) |
HN9 |
80 MHz wide baseband IF output at 321.4 MHz for frequencies less than 3.05 GHz |
HNQ |
I/Q Front Panel Output connectors with hardware for use with 89600A. |
HS1 |
Increase level of security write protects to user files |
HS7 |
Security erase software |
HT1 |
GPS Interface Card for Trimble GPS |
HWB |
Analog IF output from option 122 |
HY7 |
Improved Gain 70 MHz IF Output |
JMP |
Rear panel jumper cable |
N6171A |
MATLAB Software |
N6171A-M01 |
MATLAB - Basic Package |
N6171A-M02 |
MATLAB - Standard Package |
N6171A-M03 |
MATLAB - Advanced Package |
N9051A |
Pulse measurement software |
N9051A-2FP |
Pulse measurement software, fixed, perpetual, license |
N9051A-3FP |
Phase & Frequency Measurements |
N9051A-4FP |
Extended Analysis & Statistics |
OBO |
Delete Manual |
PS-S20-01 |
Recommended Startup assistance |
R-50C-001 |
Standard Calibration w/data. Replaced UK6 |
R-50C-002 |
Traceable Calibration standards compliant initial receipt. (ANSI-Z540/17025) |
R-50C-011-3 |
Agilent Calibration - 3 years |
R-50C-011-5 |
Agilent Calibration - 5 years |
R-50C-016-3 |
ISO 17025 Compliant Calibration - 3 years |
R-50C-016-5 |
ISO 17025 Compliant Calibration - 5 years |
R-50C-021-3 |
ANSI Z540-1-1994 Calibration - 3 years |
R-50C-021-5 |
ANSI Z540-1-1994 Calibration - 5 years |
R-51B-001-3C |
Return to Agilent Warranty - 3 years |
R-51B-001-5C |
Return to Agilent Warranty - 5 years |
R-51B-001-C |
Return to Agilent Warranty - 1 year |
R-52A-001-3 |
3 Year Calibration License (Commercial) |
R-52A-001-L |
Lifetime Calibration License (Commercial) |
R-52A-002-3 |
3 Year Calibration License (Z540/17025) |
R-52A-002-L |
Lifetime Calibration License (Z540/17025) |
RMKT |
Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UE2 |
Firmware Kit. CD-ROM. |
UK6 |
Commercial Cal Certificate with Data |