010 |
Time Domain |
014 |
Configurable Test Set Option (front panel access loops between source output and coupler input) |
016 |
Add Reciever Attenuators (35 dB in 5 dB steps) |
022 |
Extended Memory 512MB |
080 |
Frequency- Offset ( for use with mixers, converters and amplifiers) |
081 |
Reference Channel Switch (Adds internal switch to R1 Path) |
083 |
Frequency Converter Measurement Application S/W |
1A7 |
ISO 17025 Compliant Calibration |
1CM |
Rackmount Kit |
1CP |
Rackmount and Handle Kit |
550 |
4 Port Measurement Application (Enables full 4-port error correction and differential measurements on 2 Port N/A.) |
700 |
Standard test set |
711 |
Standard power range |
720 |
Extended Memory 512 MB |
810 |
Standard test set and standard power range (700+711) |
811 |
Standard test set and extended power range (700+UNL) |
812 |
Configurable test set and standard power range (014+711) |
813 |
Configurable test set and extended power range (014+UNL) |
830 |
Option Bundle Package of UNL, 014,016,080,081,and H11 |
831 |
Option Bundle Package of UNL, 014,080,081,and H11 |
85052B |
Standard Mechanical Calibration Kit, DC to 26.5 GHz, 3.5 mm |
85053B |
Verification Kit, 3.5 mm |
85056A |
Standard Mechanical Calibration Kit, DC to 50 GHz, 2.4 mm |
85056D |
Economy Mechanical Calibration Kit, DC to 50 GHz, 2.4 mm |
85057B |
Verification Kit, 2.4 mm |
85130F |
Test Port Adapter Set, 2.4 mm to 3.5 mm |
85130G |
Test Port Adapter Set, 2.4 mm to 2.4 mm |
85133D |
Semi-Rigid Cable Set, 2.4 mm |
A6J |
ANSI Z540 compliant calibration with test data |
AB1 |
Korea Quick Users Guide (Korean localization) |
AB2 |
China Quick Users Guide (Chinese localization) |
ABA |
U.S. Quick Users Guide (English localization) |
ABD |
Germany Quick Users Guide (German localization) |
ABE |
Spain Quick Users Guide (Spanish localization) |
ABF |
France Quick Users Guide (French localization) |
ABJ |
Japan Quick Users Guide (Japanese localization) |
ABZ |
Italy Quick Users Guide (Italian localization) |
H08 |
Pulsed-RF measurement capability |
H11 |
IF Access (for antenna,point in pulse,pulse profile and broadband MM wave measurements.) |
H85 |
High Power Option w/o Bias Tees. (allows RF Amplifiers between RF Source and Coupler Input) |
R-51B-001-3C |
1 year Return-to-Agilent warranty extended to 3 years |
RMKT |
Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UK6 |
Commercial calibration with test results data |
UNL |
High Power Measurement w/ Bias tees Configuration (Allows Ext. Amplifiers between RF Source and Coupler Input) |
Z5623A-H81 |
2 GHz - 20 GHz Uni Directional Pulse Test Set |
Z5623A-H83 |
2 GHz - 20 GHz Dual Directional Pulse Test Set. |
Z5623A-H84 |
2GHz-40 GHz Dual Directional Pulse Test Set |
Z5623A-H85 |
1GHz-40 GHz Dual Directional Pulse Test Set |
Z5623A-H86 |
2GHz-40 GHz Uni Directional Pulse Test Set |
Z5623A-H87 |
1GHz-50 GHz Dual Directional Pulse Test Set |
Z5623A-H88 |
1GHz-50 GHz Dual Directional Pulse Test Set (No HPIB) |
Z5623A-H89 |
10 MHz - 5 GHz Uni Directional Pulse Test Set (no HPIB) |
Z5623A-H90 |
1GHz-50 GHz Dual Directional Pulse Test Set (Test Ports on Test Set) |