Selective Modulation Analyzer, 5 to 1000 MHz
Rohde and Schwarz FMAS Overview
Rohde FMAS Performance Characteristics:
Form Factor: Benchtop
Integral Signal Source: No
Sweep Modes: No
Minimum Output Voltage: 9.98814876483344 uV
Output Impedance: 600 Ohm
No. of Receiver Channels: 1 ch
Minimum Frequency: 5 MHz
Maximum Frequency: 1000 MHz
Maximum Input Voltage: 25 V(dc+p
Signal-to-noise ratio & distortion ratio: Yes
Crosstalk: -44 dB Rohde & Schwarz, Inc. FMAS Measurements/Features:
RF Power measurement
FM measurement
AM measurement
AF voltmeter
FM stereo relay reception
Hi sensitivity & receive quali
Rohde and Schwarz FMAS All Available Options
B1 |
Filter |
B10 |
Reference oscillator OCXO, for FMA Aging 1E-9/day |
B2 |
DIST/SINAD Meter |
B3 |
Stereo decoder |
B4 |
AM/FM Calibrator/AF Generator |
B8 |
AF Analyzer/DSP Unit |
B9 |
|
C3 |
Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s). |
DCV-2 |
Documentation of calibration values |
DCV-ZP |
Printout of DCV (additional, in combination with DCV-Option only) |
FMB-C3 |
Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. |
FMB-C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. |
FMB-R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. |
FMB-R5 |
Five years of depot repair coverage, including recalibration and test data if necessary to complete the repair. |
R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
R5 |
Five years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
V-C3 |
Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. |
V-C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. |
V-R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. |
V-R5 |
Five years of depot repair coverage, including recalibration and test data if necessary to complete the repair. |
Z1 |
Service kit for modulation analyzer FMA: Extender boards with cables |
How can we help you with today?