B-B18 |
Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only) |
B-B18 |
Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
B-B18 |
Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7 |
B-B4 |
Oven quartz (OCXO) for ZVA, ZVB, ZVT |
B-K2 |
Time domain (for ZVA, ZVB, ZVT) (software license) |
B-K30 |
Noise figure measurement on 2 port devices (for ZVA and ZVT, |
B16 |
Direct generator/receiver access for 2-port ZVA24 |
B16 |
Direct generator/receiver access for 4-port ZVA24 |
B21 |
Generator attenuator port 1, mechanical, 70 dB in 10-dB-steps, 24 GHz |
B22 |
Generator attenuator port 2 mechanical, 70 dB in 10-dB-steps 24 GHz |
B23 |
Generator attenuator port 3 mechanical, 70 dB in 10-dB-steps, 24 GHz |
B24 |
Generator attenuator port 4 mechanical, 70 dB in 10-dB-steps 24 GHz |
B31 |
Receiver attenuator port 1 mechanical, 35 dB in 5-dB-steps 24 GHz |
B32 |
Receiver attenuator port 2 mechanical, 35 dB in 5-dB-steps, 24 GHz |
B33 |
Receiver attenuator port 3, mechanical, 35 dB in 5-dB-steps, 24 GHz |
B34 |
Receiver attenuator port 4 mechanical, 35 dB in 5-dB-steps, 24 GHz |
B7 |
Measurements on pulsed signals. Pulse Profile,Recording time up to 25ms, up to 30MHz bandwidth |
B7 |
Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth |
B8 |
External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E |
C3 |
THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
C3 |
THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
C5 |
FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
C5 |
FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
DCV-2 |
Documentation of calibration values |
DCV-ZP |
Printout of DCV (additional, in combination with DCV-Option only) |
DKD |
ZVA24 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
K10 |
Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT. |
K17 |
Increases the receiver bandwidth to 5MHz (software license) |
K27 |
Two internal pulse generators (for ZVA and ZVT) (software license) |
K4 |
Mixer- and frequency converting measurements for ZVA and ZVT (software license) |
K5 |
Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required) |
K6 |
True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports |
K7 |
Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth |
K8 |
Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4) |
K9 |
Measurement of group delay on frequency converters without LO access (for ZVA, ZVT; |
R3 |
THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
R3 |
THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
R5 |
FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
R5 |
FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |